Maintenance of automatic hard capsule filling Machine
(1) when the machine is in normal operation for a long time, the parts in direct contact with the medicine should be cleaned regularly, and when the batch of the medicine is replaced or the time of discontinuation is longer, It should also be cleaned up.
(2) the transmission mechanism under the machine working table should often add a proper amount of lubricating oil (grease) to reduce the wear of the moving parts.
(3) the main drive reducer should check the oil quantity once a month and refuel in time when it is insufficient. The lubricating oil is replaced once every half a year; the turntable indexing box needs to replace the lubricating oil once every 3000 hours, and 90# oil is generally used.
(4) the safety clutch plays a protective role when the machine is overloaded, and the clutch should not slip when the load is normal, However, since skidding may also occur for a long period of time, the round nut of the clutch can be tightened up when the slip occurs in normal use. In order to ensure the normal operation of the machine and play a protective role.
(5) the vacuum separator of the vacuum system mainly inhale the capsule into the upper and lower modules and separate the cap and body in the filling of the hard capsule, if the capsule cannot be capped, Body separation, subsequent filling will not proceed. The rotating disc of the machine rotates in one position and the main axis of the machine rotates for 1 week. The vacuum separator moves up and down once under the action of the cam. If the capsule cap is not separated smoothly, the gap between the upper plane of the vacuum separator and the lower plane of the lower module should be checked. The clearance is excessive so that the vacuum degree of the vacuum system cannot reach the cap, The vacuum degree required by bulk separation (about 0.05 MPA), the clearance is too small and easy to produce collision deformation of the lower module. When the position of the vacuum separator needs to be adjusted, the main motor shaft is rotated with the handle, so that the vacuum separator rises to the high position of zui and releases the locking nut at the two ends of the regulating rod under the machine table. One is a right-handed nut), then rotate the adjusting rod to adjust the height of the vacuum separator, then lock the nut, and use the handle to rotate the main motor shaft test until suitable. The vacuum degree is read out on the vacuum meter of the machine operating panel. When the vacuum degree is too high, the vacuum regulating valve can be properly opened, and when the vacuum degree is too low, the vacuum regulating valve can be turned off or off. The vacuum system filters are regularly turned on to clean up the clogged dirt to ensure that the vacuum system has sufficient vacuum.