Email: manager@richpacking.cn, WhatsApp / Wechat : +86-13826093596


Details

Home  > NEWS  > Industry News > Details

Daily Problems Of Blister Packing Machine

Published:2021-07-16Author:Sources:Views:403

NO.

Left: The Listed Questions

Right: The Corresponding Answers To Left

1

What other device does the machine have to use?

The machine needs to receive electricity, receiving water and air compressor before use; if receiving water, can use natural water or circulating water; if circulating water needs to buy water pump; can also bring water cooler. Generally, 260 machines must be equipped with cold coolers.

2

Detailed Size of package

Both the pvc and aluminum plastic paper core internal diameter are 76 mm, and the PVC roll film maximum diameter is 300mm; aluminum foil is 250mm;

3

10mm circular tablets, 14 tablets, aluminum blocks, machine production is the 260?

Can be out of 5 boards, blunt is 30 times / points

4

The size of the essence plate is a 48x30mm; 160 device?

One out and three, this kind of can use a drag three peristaltic pump, namely a peristaltic pump with three material mouths, the cost price is 7,000 yuan

5

If the mold is the same size, but the depth is different, do you need to do a new set?

No, as long as the mold mold and hot seal mold;

6

What is the fastest number of 260 equipment?

The fastest number is 40 One points 

7

Number 00 capsule, one edition of 10,260 equipment can be a few editions

It is one out and three

8

Honey plate 50x32,260 out how much?

One out of eight is the answer

9

And how many is 140?

The correct answer is truly 10kg.

10

Whether the cursor pair version must have a touch screen

It can be without touch screen

11

No.3 capsule, aluminum packaging, 80 equipment can row how much grain

Up to 6 rows is correct

12

Maximum load bearing of 130 aluminum and plastic machine package material

Both the PVC and the aluminum foil are 30kg

13

Dimensions and tolerance of the cursor

Width 3mm, length 5mm or 6mm, tolerance is ± 0.5

14

Does the height of the brush adjust too high to produce missing particles?

The distance between the brush from PVC is generally 1mm, and depends on the thickness of the tablet

15

160 has another solution

It can make two accumulators

16

The customer requires explosion-proof

To confirm that the electrical explosion-proof? Does the motor also require the explosion-proof work

17

Can the customer's elevator length is 2m, Does our 150 equipment go in

Demolition is ok, the net length is 1.8m, width is 0.65m

18

Dimensions of the DPP-160R

2350x650x1550.

19

The maximum packaging size of the model DPP-160R

It is 155x100x15mm.

20

The voltage of DPP-130 aluminum is generally 220V or 380V

The correct answer is 220V.

21

What is the maximum plate size of the DPP-130 aluminum aluminum

The correct answer is 105x65.

22

DPP-90 Pack 15g chocolate sauce, usually a few at a time

The correct answer is one out or two.

23

Can aluminum only use backwords?

Yes, typing the positive words will be a group, can not see clearly

24

What is the precision of the peristalsis pump?

Depending on the filling volume, it is generally positive or negative%; such as 1ml perfume, the accuracy is generally ± 1%

25

After the general depth of more than 30 millimeters, the normal speed of the machine is about 15 times, the specific depends on the final confirmed sample

Generally only DPP-160R and DPP-260 devices can achieve the deepest 35mm

26

How to adjust the PVC and aluminum foil

Step 1: the width of PVC and the width of the white ring, PVC needs to be in the center of the mold;

The second part: The width of the guide on both sides of the bubble needs to be adjusted to the edge of the bubble, so that the bubble will not shift left and right during operation;

There are also different mold thickness will also have deviation, so each replacement of the mold needs to adjust the height of the mold;

The nuts referred to in the picture are the adjustment nuts, there are a total of four, generally the most suitable position is that the two molds just stick to and will not be air leakage is verified one by one.

Adjust the mold level needs to pay attention to, the pressure can not be too large, too large the machine will vibrate, will produce noise

27

Can the big honey pill of traditional Chinese medicine be added automatically

The correct answer is Generally hand feeding.

 


DOWNLOADS image.png
Tags:
您好,是时候升级你的浏览器了!你正在使用 Internet Explorer 的过期版本,Internet Explorer 8 可以为你提供更快、更安全的浏览体验,提供更好的隐私保护。立即下载