What are the precautions for the disassembly and assembly of the tablet press machine?
Installation adjustment and use
1. Installation and adjustment of the die:
1.1 Preparation before die installation: Remove the hopper and feeder. Open the right door and turn the handwheel to clean the turntable working surface, the die hole and the die to be installed. Rotate the pressure adjustment pulley to minimize pressure. Remove the undershoot loading and unloading rails.
1.2 Installation of the middle mold: Rotate the middle mold fastening screw on the turntable about 1 mm from the outer circumference of the turntable. Be careful not to touch the parts such as the powder suction nozzle. Do not touch the head of the screw when the middle mold is loaded. . The medium-mold device is tight, and it should be placed smoothly. Put the rod into the upper punching hole and gently tap it in. After the middle mold enters the die hole, the plane is not higher than the plane of the turntable, and then the screw is tightened.
1.3 Installation of the upper punch: Firstly remove the tongue, then insert the upper punch into the hole, rotate the punch with the thumb and forefinger, check the flexibility of the head to slide up and down the middle mold, and no jamming is acceptable. Turn the handwheel again until the neck of the punch contacts the parallel rail. The upper punch is fully assembled and the tongue is fitted.
1.4 Undershoot installation: Install according to the method of punching, and install the underload loading and unloading rails.
Type 1.5 operation: After the complete set of molds is loaded, turn the handwheel to rotate the turntable for 2 weeks, and observe the upper and lower punches entering the middle die hole and running on the track. No jamming and collision phenomena are acceptable. It should be noted that the highest point (ie, the exit) should be 0.1 to 0.3 mm above the turntable working surface. Close all doors, turn on the motor, idle for 2 minutes, and use it until it is running smoothly.