According to the adhesion of effervescent tablets, it is basically unavoidable. Good physical, technological, and humidity control may delay the time of adhesion. If it is not effectively controlled, it can start to produce adhesion in 3-5 minutes. Can't continue production at all
At present, most of them solve the problem of adhesion by insert gasket (Teflon).automatic press tablet: In general, such gasket can relieve the time of adhesion, which can be pressed for 1-2 hours, and the time may be pressed for a long time according to physics and formula.
Because of the hardness problem of Teflon, the pressure of automatic pill press machine pressing effervescent tablets is large, the life of gaskets will be reduced, and the inlaid gaskets can be replaced and low cost, which is only suitable for flat oblique effervescent tablets or tablets.
The reason of drawing die is that the diameter of effervescent sheet is too large, the contact surface between punching rod of automatic pill press machine and middle die of automatic pill press machine is too much. When the high velocity pressing sheet produces heat and the powder is worn in the middle die, the main reason of drawing die automatic pill press machine of or adding felt up and down under the lower punch of the automatic pill press can solve the problem of astringent punching.